Product overview

  • Type: Thermal disc limit switch (bimetallic)

  • Model: T-O-D 60T21

  • Function: Open or close electrical circuit in response to temperature; provides over-temperature protection and control for HVAC equipment.

Key specifications

  • Temperature setpoint: 60°C (nominal)

  • Differential: Manufacturer-specified hysteresis (typical for disc-type limits; check unit label for exact value)

  • Contact configuration: SPST or SPDT (verify label)

  • Voltage/current ratings: Match OEM equipment requirements — consult unit label or equipment manual for maximum switching voltage and current

  • Terminations: Quick-connect or screw terminals depending on version

  • Mounting: Panel or chassis mount with threaded bushing or bracket (model-dependent)

  • Materials: Bimetal thermal disc element with metal housing and insulating terminal block

Applications

  • Furnace and boiler primary or secondary high-limit protection

  • Packaged rooftop units and air handlers

  • Water heaters and steam systems

  • Industrial temperature monitoring and safety cutouts

Installation notes

  • Mount in the location specified by the equipment manufacturer (typically near the heat source)

  • Ensure good thermal contact with the surface if required; use thermal paste if recommended

  • Observe correct orientation and secure mounting to avoid vibration-related failures

  • Wire according to equipment wiring diagram; de-energize power before installation

  • Replace like-for-like: match setpoint, mounting style, and electrical ratings

Maintenance and testing

  • Periodically inspect for corrosion, loose terminals, or physical damage

  • Test operation by performing controlled heat cycling per equipment service procedures

  • Replace if contacts are pitted, if switch fails to open/close at specified temperature, or if mechanical deformation is present

Ordering information

  • When ordering replacement, provide: equipment model, existing part number, setpoint (60°C), mounting type, and terminal style

  • OEM-equivalent replacements recommended for guaranteed fit and function

Safety

  • Shorten.

T-O-D 60T21 Thermal Disc Limit Switch

Product overview

  • Type: Thermal disc limit switch (bimetallic)

  • Model: T-O-D 60T21

  • Function: Open or close electrical circuit in response to temperature; provides over-temperature protection and control for HVAC equipment.

Key specifications

  • Temperature setpoint: 60°C (nominal)

  • Differential: Manufacturer-specified hysteresis (typical for disc-type limits; check unit label for exact value)

  • Contact configuration: SPST or SPDT (verify label)

  • Voltage/current ratings: Match OEM equipment requirements — consult unit label or equipment manual for maximum switching voltage and current

  • Terminations: Quick-connect or screw terminals depending on version

  • Mounting: Panel or chassis mount with threaded bushing or bracket (model-dependent)

  • Materials: Bimetal thermal disc element with metal housing and insulating terminal block

Applications

  • Furnace and boiler primary or secondary high-limit protection

  • Packaged rooftop units and air handlers

  • Water heaters and steam systems

  • Industrial temperature monitoring and safety cutouts

Installation notes

  • Mount in the location specified by the equipment manufacturer (typically near the heat source)

  • Ensure good thermal contact with the surface if required; use thermal paste if recommended

  • Observe correct orientation and secure mounting to avoid vibration-related failures

  • Wire according to equipment wiring diagram; de-energize power before installation

  • Replace like-for-like: match setpoint, mounting style, and electrical ratings

Maintenance and testing

  • Periodically inspect for corrosion, loose terminals, or physical damage

  • Test operation by performing controlled heat cycling per equipment service procedures

  • Replace if contacts are pitted, if switch fails to open/close at specified temperature, or if mechanical deformation is present

Ordering information

  • When ordering replacement, provide: equipment model, existing part number, setpoint (60°C), mounting type, and terminal style

  • OEM-equivalent replacements recommended for guaranteed fit and function

Safety

  • Shorten.